Castle Altdöbern

Sealing of cables and pipes according to DIN 18195 Part 6
Use of fixed and loose flanges according to DIN 18195 Part 6 and 9
The task: Rehabilitation measures at the castle by the construction company BUST-GmbH Stramke from Lohsa. Secure house entries had to be installed in the humid and untight basement. Ground conditions and critical ground water level in the area required a suitable sealing (black tank). Therefore house entries were made with stainless steel wall sleeves with fixed and loose flange type HRD-FUF (for concreting) as well as HRD-FUFA (for dowelling) with the press seals HSD. The planner designed therefore loading case according to DIN 18195-6 with hydrostatic pressure from the outside.